Accelerators Laboratory |
Multidisciplinary research using charged particle beams |
Facilities |
Horizontal electron Linac ALIN 10 - beam energy = 6.2MeV - pulse current = 75mA - beam power = 160W - frequency = 100Hz - pulse duration= 3.5µs |
Gel permeation chromatograph (GPC) - Breeze System, Waters - binar pomp 1525, - detector with refractive index 2414, - temperature system control - Software: Breeze v. 3.30 SPA |
FLASH 2000 Series CHNS/O Analyzer, Thermo Scientific - autosampler for liquid / solid samples MAS 200R, - electronic microbalance with 6 decimals Mettler Toledo, - thermal conductivity detector (TDC) - Software: Eager Xperience |
Termobalance DENVER IR 200 - temperature range: (30 – 210)oC ± 10oC - balance capacity: 100 g ± 0,001 g |
VARIAN CARY 100 Bio Spectrophotometer - (UV)-(Vis) for solid and liquid samples - 3 sets of complex acccesories - spectrophotocolorimetric analysis (Color Application) - wavelength range : 190 – 900 nm - Software: Cary WinUV v. 3.10 |
Spectrophotometer FTIR Tensor 27 - Software: Opus v. 6.5 |
pH-meter WTW model inoLab® 7110 - measure range pH: 0 – 14 |
Electronic balance Denver AA-200 - weighting range: (0 – 200) g, - measuring error : ± 0,0001 g |
Magnetic stirrer with thermal control - 9 sites for stirring - spedd range (100.....200) rpm - intermittent stirring |
Centrifugal machine EBA 20 - max. capacity : 8 x 15 ml, - speed: 6 000 |
Water distiller |
Water bidistiller |
Vertical electron Linac ALID 7 - beam energy = 6MeV - pulse current = 130mA - beam power = 670W - frequency = 250Hz - pulse duration= 3.75µs |
Microwave generator Sairem 25W - step adjustment : 0.1W - frequency: 2450 MHz |
Microwave generator Sairem 2kW - step adjustment : 1W - frequency: 2450 MHz |
Etuva Memmert |
Centrifugal machine ROTOFIX 32 - max. capacity : 4 x 100 ml si 6x85ml - speed: 6000 RPM |
Optical fiber Thermometer OPSENS. - it works in electromagnetic intense field - software Soft Sens -temperature range: - 50 - +350oC |
Plasma RF System - power: 100W - frequency: 13.56 MHz - CCD fast videocam for plasma diagnostics: 100k frames / second - 20mW laser diode at 650nm - coaxial gun plasma jet at 2KV |
Electron beam 15KeV - plasma electrons source - magnetic lens focalization - sistem vid inalt cu pompa difuzie with diffusion pump |
ENDA-600 Series Stack Gas Analyzer System - SO2, NOx, CO, CO2 and O2 monitoring - repetability: ≤ ±1.0 % from entire scale - hardware and software integrate |
Universal dozimeter UNIDOS - PTW - advanced Markus Chamber type 34045 -Roos Chamber Type 34001 |
Research Areas |
Copyright © 2012 National Institute for Laser, Plasma and Radiation Physics. | site map | contact | |
Chemistry
Polyelectrolytes Elastomers Pollutants removal Nanoparticles
Biology
Biomedical studies Biological Decontamination
Plasma
Microparticles Acceleration in Plasma
Theory
Electron Beam Dynamics Theoretical and Computational Methods in Solids Processing with Lasers |
HAAKE Viscotester ® 550 - rotation speed: (0,5 – 800) rpm - measuring temperature: (-20 – 100)oC - senzors: 3 standard sensors and 1 sensor for immersion - Software: HAAKE v. 3.50.0010 |